In-depth deep root cause analysis
When Failure Analysis Level 2 services don’t provide enough data, the following Failure Analysis Level 3 tests are used:
- Cross Section
- Parallel Lapping
- Chemical Deprocessing
- Multipurpose Bond Tester (includes Bond pull and Ball Shear)
- SEM/EDX analysis
- Focused Ion Beam (FIB)